Browse all practice questions for the Fire Pump Run Test Operator Certification Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Fire Pump Run Test Operator Certification Practice Test course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • What weekly action should be taken regarding the condition of flexible hoses and connections?
  • Lube oil heater maintenance frequency?
  • What weekly action is specified for water pump(s)?
  • The installed safety relief valve shall be allowed to discharge under which condition?
  • If discharge valves are seized and cannot be opened during a run test, what is the proper course of action?
  • Which entities should be notified for a significant abnormality observed during testing?
  • Equalize charge (battery) maintenance requires which weekly action?
  • Which pump would be used where a suction lift is needed, such as from an underground reservoir, well river, or lake?
  • The oil level in the motor sight glass should be within which range?
  • Any person who violates any provision of this chapter or any regulation or building standard adopted by the State Fire Marshal pursuant to Section 13195 is guilty of?
  • The controller pilot light should be what during normal operation?
  • The motor should accelerate to which speed during testing?
  • During a zero-flow test, what actions are performed and what is its primary purpose?
  • Backflow prevention is used to keep water from entering which system?
  • If a run test reveals excessive engine exhaust emissions, what steps should be taken?
  • What weekly maintenance should be performed on drain exhaust condensate traps?
  • What is the weekly maintenance for the condition of flexible hoses and connections?
  • What is the primary purpose of a running test on a fire pump?
  • What happens when the transfer switch operates?
  • What is the consequence of insufficient net positive suction head (NPSH) on pump operation?
  • Specific gravity or state of charge of the battery should be checked at what interval?
  • How do you identify and correct an air-bound priming system during a run test?
  • If the license fee is not paid on or before which date preceding the license year, a 50 percent penalty applies?
  • Which weekly maintenance action is recommended for the exhaust system to prevent leaks?
  • The transfer switch normal pilot light should be what during normal operation?
  • What would be the peak flow rate of a fire pump?
  • Which instrument indicates the oil level in the motor?
  • For causing great bodily injury or death by maliciously constructing a system, what is the offense classification?
  • Circuit breakers or fuses: Which action sequence is recommended?
  • If the cranking voltage on a 12-volt system exceeds 9 volts, which action is specified and how often?
  • What is the difference between auto-start and manual start mode for a fire pump, and when should each be used during a run test?
  • During a run test, rising temperature in the pump bearing housing is observed. What are the possible causes and the recommended remedy?
  • Voltage readings at the motor within __% below and __% above rated nameplate is acceptable?
  • What is the first indication of a pump operating without water in its casing?
  • What is the role of standby personnel during a run test?
  • Tank Level: Which maintenance action sequence is recommended?
  • In NFPA 20, what are the primary tests included in an annual run test?
  • How can you verify the pump is delivering the correct flow at the correct head when test flow is not easily measured?
  • Which of the following safety steps should be observed when performing a run test under real-fire conditions or with variable water supply?
  • During a run test, abnormal vibration may be caused by which of the following, and how should it be diagnosed?
  • Abnormalities observed should be reported to which party?
  • Define net positive suction head in the context of fire pump operation and why it's important.
  • The controller selector switch should be in which position for automatic control?
  • If cranking voltage exceeds 9 V on a 12 V system, what action and cadence are specified?
  • Suction reservoir level should be kept at what level?
  • Suction reservoir level should be kept at what level?
  • What is the purpose of annunciator and alarm testing during run tests?
  • In the absence of a specified designee, who shall be considered the impairment coordinator?
  • Why is calibration of pressure gauges essential before a run test?
  • Which of the following describes the steps to perform a post-test inspection after a run test?
  • During ATS testing, what is the purpose of simulating a power failure while the pump is at peak load?
  • What should be done to ensure safe water supply during a run test?
  • The reverse phase alarm pilot light should be in which state under normal conditions?
  • The installed safety relief valve shall be?
  • Which measurement is not typically recorded during a full-flow test on a fire pump?
  • How would you calculate the minimum acceptable discharge pressure during a test for a given system head, and what fluid properties matter?
  • During a pump run test, how does ambient temperature affect results and what precaution should you take?
  • Abnormalities observed should be reported to whom?
  • What steps would you take if during a test, the discharge pressure falls below the required level while the engine speed remains at rated?
  • Exercise isolation switch & CB: Which action and cadence is recommended?
  • How would you differentiate between cavitation and bearing noise during a run test?
  • Electric fire pump run time during the test?
  • In a fire pump run test, ballast or surge tanks dampen pressure fluctuations and water hammer; when would they affect test results?
  • What indicates that engine oil or coolant readings are abnormal and require remediation before proceeding?
  • The state agency responsible for adopting a schedule of fees paid by licensees to cover administrative costs is which entity?
  • During a run test, what observation indicates that the engine cooling system is functioning properly?
  • What is a common cause of pump suction loss or discharge pressure failure?
  • Any person who maliciously constructs or maintains a system which proximately results in great bodily injury or death is a felony punishable by?
  • A license may be revoked or denied for which of the following reasons?
  • The normal phase rotation pilot light should be in which state?
  • What is the purpose of a remote annunciator panel, and what information should be displayed during a run test?
  • How does a static test differ from a running test for fire pumps?
  • Battery case exterior maintenance should be performed on which cadence?
  • For a 24-volt system, cranking voltage over 18 volts requires what action and cadence?
  • Any person who maliciously constructs or maintains a system which is known to be inoperable or impairs the operation shall be subject to?
  • What is the significance of recording engine oil level and coolant during run tests, and how would you interpret abnormal readings?
  • A license may be revoked or denied for which of the following reasons?
  • Notification to alarm facility should be sent to which entities?
  • General Inspection Electrical system: Which action sequence and cadence is recommended?
  • Which measurements are typically monitored to assess pump performance during a run test?
  • What position should the suction bypass valve be in?
  • Which issue is a common cause of reduced suction or discharge pressure in a pump?
  • Which symptom most clearly indicates cavitation during a run test?
  • What is the primary purpose of a jockey pump in a fire pump system and how is it activated?
  • What is the purpose of conducting a full-flow test on a fire pump and what measurements are typically recorded?
  • Water in system: Which maintenance action sequence is recommended?
  • Read which flow condition as follows?
  • Which statement describes the normal phase rotation indicator when rotation is correct?
  • After starting the engine and allowing the diesel fire pump to reach operating RPM, what must be verified before placing the pump in service?
  • Why is it important to verify the engine governor/engine speed during run test, and what is a typical target RPM range for a diesel fire pump?
  • Explain the procedure for re-priming after a loss of prime during a run test.
  • Gauges shall be replaced every ___ years or tested every ___ years using a calibrated gauge?
  • What are the common indicators of an air leak in the suction line during a run test?
  • Which statement best describes the function of the non-return (check) valve in the discharge line during a run test?
  • Valves and fire department connections shall be?
  • How is a jockey pump typically activated in a fire pump system?
  • Which of the following is NOT listed as a common cause for a pump not achieving starting at the scheduled time in auto mode during a run test?
  • What is the required run time for the diesel engine during the weekly run test?
  • The annual renewal period shall begin on December 31 and end on January 1 preceding the license year. Which dates define this period?
  • What is the purpose of placing barriers around the test area during a run test?
  • Suction bypass valves should be set to what position during normal operation?
  • For installations with an automatic transfer switch, which tests should be performed?
  • For the jacket water heater, what is the required inspection frequency?
  • What is the purpose of logging data during a run test?
  • Lockout/tagout procedures during a run test are used to prevent what risk?
  • What is the first critical step in the re-priming process?
  • During testing, the flow readout includes which measurements?
  • During inspection, the pump assembly should appear to be in which condition?
  • In a fire pump system, why is a relief valve used and how should it be tested for proper operation?
  • Battery electrolyte level should be checked how often?
  • Backflow prevention devices are designed to prevent backflow into which source?
  • Penalty for malicious inoperable system causing great bodily injury or death?
  • If cranking voltage on a 24 V system exceeds 18 V, what action and cadence should be followed?
  • Which tests shall be performed?
  • Tank float switch: Which action sequence is recommended?
  • Which party designates an impairment coordinator if no designee is specified?
  • What is the most common cause of horizontal pump failure?
  • The offense of intentionally constructing or maintaining a system that results in great bodily injury or death is what?
  • What maintenance instruction applies to exhaust system leakage during the run test?
  • Explain the role of the transfer switch in a fire pump system run test and how it is tested.
  • Which devices should be tested together as part of the emergency power testing program?
  • What post-test activity ensures the performance data is captured for review?
  • Diesel engine run time during the run test?
  • Which maintenance steps are specified for solenoid valve operation in the run test procedure?
  • When testing a fire pump with a vertical turbine versus an end-suction pump, which considerations must be made?
  • Before operating a horizontal pump, what is the acceptable drop per second in the packing?
  • Which items should be captured in the run test record after testing?
  • What should you do if a gauge indicates an abnormal discharge pressure reading during the run test?
  • Battery case exterior clean & dry: Which action sequence is recommended?
  • Which maintenance sequence is required for valves and fire department connections?
  • The peak flow rate of a fire pump is 150% of its rated flow. Which statement is true?
  • The annual license shall be valid for which period?
  • The annual license validity period runs from January 1 to December 31. Which statement best reflects this period?
  • What is the role of the suction gauge in a run test, and what readings indicate normal operation?
  • The purpose of the inspection shall be to verify that the pump assembly appears to be?
  • General electrical system inspection cadence: Which action sequence is recommended?
  • Why is it essential to keep the test area clear of civilians and vehicles during a run test?
  • Which of the following is the penalty for violating this chapter's provisions or regulations adopted by the State Fire Marshal?
  • Which state should the observed isolating switch for standby sources be in during normal operation?
  • Oil Level: Which maintenance action sequence is recommended?
  • What is the proper sequence for safely shutting down a fire pump after a run test?
  • During routine checks, what action sequence is recommended for flexible hoses and connections?
  • For the battery charger and charge rate, what routine is required?
  • Flexible hoses & connections: Which action sequence and cadence is recommended?
  • Who will assign an impairment coordinator to comply with Chapter 15 requirements?
  • When measuring motor voltage, what tolerance is acceptable relative to the rated nameplate value?
  • How would you identify a leak in the discharge piping under test, and what steps would you take to locate and repair it?
  • Circuit protection devices inspection: Which action sequence is recommended?
  • What weekly action should be taken to ensure adequate cooling water to the heat exchanger?
  • Gauges shall be inspected to verify they are in good condition and that normal pressure is being maintained?
  • Increasing engine speed beyond the pump rated speed is acceptable?
  • What is the function of the governor during a diesel fire pump run test?
  • For weekly checks of the general electrical system, which maintenance sequence is recommended?
  • Which instrument is commonly used to locate hidden leaks during a pressure test?
  • When should notification to the alarm facility be performed?
  • What action should be taken if a gauge is not accurate?
  • What does discharge pressure primarily indicate during a run test?
  • Which condition is identified as the most common cause of horizontal pump failure?
  • What is the purpose of a pressure relief valve in the fire pump discharge system, and how should it be tested during a run test?
  • Why should the shutdown be documented in the test record?
  • Which statement best describes the AHJ roles?
  • Which facility should be notified when the alarm triggers?
  • Wet pit suction screens should be checked and cleaned when?
  • Define cavitation in a fire pump impeller and identify typical indicators observed during a run test.
  • What is the effect of ballast tanks on transient readings during rapid load changes or pump trips?
  • How does a fire pump run test verify ability to sustain rated discharge pressure under fluctuating demands?
  • In a suction lift scenario, which pump type is appropriate?
  • For how long should the property owner retain testing and maintenance records?
  • Which weekly action is specified to protect the cooling system, specifically the heat exchanger?
  • How do you verify proper priming of a positive displacement fire pump, and what are signs of improper priming?
  • Why is it important to test the jockey pump function separately from the main pump during run testing?
  • What is the minimum observed fuel tank level specified?
  • During a run test, which sequence correctly describes starting a diesel fire pump and preparing it for service?
  • Pump packing glands should have?
  • What is the purpose of a check valve in the discharge piping during a run test?
  • What action should you take if the suction gauge indicates abnormally low suction pressure during a run test?
  • Which statement about AHJ membership is true?
  • Which statement best describes priming differences between end-suction and vertical turbine pumps during testing?
  • Which audible cue indicates a pump may be running dry?
  • Which statement about the Authority Having Jurisdiction (AHJ) is correct?
  • During normal operation, which statement describes the suction bypass valve position?
  • What is the role of a check valve in the suction line, and how would you verify it is functioning during a run test?
  • Fuel tank level should be maintained at what level?
  • Which records shall be maintained by the property owner for the life of the system?
  • When inspecting the isolating switch, what should be the state of the standby source?
  • If a high vibration reading exceeds acceptable limits during a run test, what is the first step?
  • Cooling system Level: Which action sequence is recommended?
  • Who has the right to establish a secondary schedule of fees?
  • Which factors determine the need to implement a standby power source for a run test?
  • What should be documented to validate the start/stop sequence during a run test for compliance and traceability?
  • Suction bypass valves should be set to what position?